Aortic valve model for cardiac surgery training

LifeLike Aortic Valve Model – Cardiac Surgery Training Simulator

Calcified / 17 mm / Single
£190.00 VAT included
Sale price  £190.00 VAT included Regular price 
Skip to product information
Aortic valve model for cardiac surgery training

LifeLike Aortic Valve Model – Cardiac Surgery Training Simulator

including VAT
PRODUCT OVERVIEW

LifeLike Aortic Valve Model – Cardiac Surgery Training Simulator

SurgiSim
Manufacturer SurgiSim
Type Cardiac & Cardiothoracic Surgical Training
Availability Available
Use Surgical simulation & training

Training applications

Surgical skills
Universities
Simulation centres
Teaching hospitals
Instructor-led training
Skills development
i
Institutional orders

Purchase orders are welcome from universities, NHS organisations, hospitals, simulation centres and approved institutional customers.

Choose your configuration

Select the configuration required.

Choose Options

Choose Size

Choose Pack Size

Your configuration £190.00
P
American Express Apple Pay Diners Club Discover Google Pay Klarna Maestro Mastercard PayPal Shop Pay Union Pay Visa
Purchasing multiple units? Institutional pricing available.

In stock at our Huntingdon warehouse
Normally dispatched within 1–2 working days.

Product information

Training applications and specification

Detailed product information to help you assess suitability, training applications and institutional requirements.

LifeLike BioTissue · Cardiac Surgery Training

Realistic aortic valve replacement and repair practice

The LifeLike Aortic Valve Model provides a realistic synthetic training platform for developing cardiac valve replacement, repair and precision suturing techniques in a controlled learning environment.

19–27 mm sizes 0.2 mm leaflets Integrated coronary arteries Base compatible

LifeLike Aortic Valve Model

Designed for cardiothoracic surgical education, this model combines a robust aortic root with thin valve leaflets, an ascending aorta and coronary arteries. It enables trainees to practise the tissue handling, suture placement and procedural steps involved in aortic valve surgery.

The model is suitable for individual skills development, supervised teaching, cardiac surgery workshops and structured simulation programmes.

01

Detailed valve anatomy

Incorporates an aortic root, thin valve leaflets, ascending aorta and coronary arteries for focused procedural training.

02

Procedure-focused training

Supports the development and evaluation of valve replacement, valve repair and cardiac suturing techniques.

03

Multiple valve sizes

Select from 19 mm, 21 mm, 23 mm, 25 mm or 27 mm models to suit different teaching requirements.

Training applications

  • Aortic valve replacement training
  • Aortic valve repair techniques
  • Cardiac valve suturing practice
  • Suture placement and spacing
  • Surgical instrument handling
  • Cardiothoracic skills assessment

Model features

  • Robust synthetic aortic root
  • Thin 0.2 mm valve leaflets
  • Integrated ascending aorta
  • Simulated coronary arteries
  • Non-toxic and biohazard-free material
  • Odourless and ready for training use

Choose your valve size

Select the required model using the Valve Size menu above. Each size is designed to accommodate the corresponding replacement valve size during simulated training.

Valve size Ventricle height Ascending aorta height Leaflet thickness
19 mm 20 mm 25 mm 0.2 mm
21 mm 20 mm 25 mm 0.2 mm
23 mm 20 mm 25 mm 0.2 mm
25 mm 25 mm 30 mm 0.2 mm
27 mm 25 mm 30 mm 0.2 mm
Additional specifications: Each listed size has simulated coronary arteries measuring 3 mm internal diameter and 4 mm external diameter. Aortic wall thickness is approximately 1.75 mm.

Who is it designed for?

  • Cardiothoracic surgical trainees
  • Cardiac surgery residency programmes
  • Medical schools and universities
  • Teaching hospitals
  • Surgical skills laboratories
  • Simulation centres and training workshops

What is supplied?

One LifeLike Aortic Valve Model in the valve size selected above.

Please note: The mounting base, surgical instruments, sutures and replacement valve are not included. The LifeLike Aortic Valve Base is available separately.

Special configurations and institutional orders

LifeLike also manufactures additional configurations, including 29 mm models, calcified valves for simulated aortic stenosis and institutional pack quantities. Contact SurgiSim for availability and a quotation if these configurations are required.

Related cardiac training products

Frequently asked questions

Which valve sizes are available on this product page?

The selectable sizes are 19 mm, 21 mm, 23 mm, 25 mm and 27 mm. Contact SurgiSim if you require another manufacturer configuration.

Can the model be used for aortic valve replacement training?

Yes. It is designed for practising and evaluating aortic valve replacement, valve repair and associated cardiac suturing techniques.

Does the product include the Aortic Valve Base?

No. The valve model and mounting base are separate products. The Aortic Valve Base can be ordered alongside the model.

Is a calcified version available?

LifeLike manufactures calcified configurations for simulating aortic valve stenosis. Please contact SurgiSim for current availability and institutional pricing.

This product is intended exclusively for professional education, simulation and surgical skills training. It is not intended for implantation or clinical use on patients.

You may also like