{"product_id":"lifelike-biotissue-lifelike-long-femoral-leg-simulator-no-pump-1267","title":"LifeLike BioTissue Long Femoral Leg Simulator","description":"\u003cdiv class=\"product-description\"\u003e\n  \u003ch2\u003eRealistic Femoral Popliteal Bypass and Graft Tunnelling Training\u003c\/h2\u003e\n\n  \u003cp\u003e\n    The \u003cstrong\u003eLifeLike Long Femoral Leg Simulator\u003c\/strong\u003e is an advanced\n    vascular surgery training model designed for practising\n    \u003cstrong\u003efemoral popliteal bypass, vascular anastomosis and graft tunnelling\u003c\/strong\u003e\n    in a realistic full-leg configuration.\n  \u003c\/p\u003e\n\n  \u003cp\u003e\n    The simulator features three pre-cut operative openings located at the\n    groin, above the knee and below the knee. These provide access to\n    replaceable LifeLike femoral artery models while allowing trainees to use\n    surgical instruments from clinically relevant positions and angles.\n  \u003c\/p\u003e\n\n  \u003cp\u003e\n    Internal channels connect the operative openings, enabling learners to\n    practise tunnelling a vascular graft along the leg before completing the\n    proximal and distal anastomoses. This makes the model particularly suitable\n    for structured training in femoral-popliteal bypass procedures.\n  \u003c\/p\u003e\n\n  \u003ch2\u003eKey Features\u003c\/h2\u003e\n\n  \u003cul\u003e\n    \u003cli\u003eFull-length adult male leg simulation model\u003c\/li\u003e\n    \u003cli\u003eThree pre-cut operative openings\u003c\/li\u003e\n    \u003cli\u003eGroin, above-knee and below-knee surgical access\u003c\/li\u003e\n    \u003cli\u003eInternal channels for realistic graft tunnelling practice\u003c\/li\u003e\n    \u003cli\u003eDesigned for femoral-popliteal bypass simulation\u003c\/li\u003e\n    \u003cli\u003eSupports end-to-end and end-to-side vascular anastomosis training\u003c\/li\u003e\n    \u003cli\u003eCompatible with replaceable LifeLike femoral artery models\u003c\/li\u003e\n    \u003cli\u003eAvailable with or without a pulsatile pump system\u003c\/li\u003e\n    \u003cli\u003eNon-toxic, biohazard-free and odourless training platform\u003c\/li\u003e\n    \u003cli\u003eEasy to prepare, maintain and incorporate into skills sessions\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch2\u003eClinical Skills and Procedures\u003c\/h2\u003e\n\n  \u003cp\u003e\n    The Long Femoral Leg Simulator can be used to develop, practise and\n    evaluate the complete sequence of skills involved in lower-limb vascular\n    bypass surgery, including:\n  \u003c\/p\u003e\n\n  \u003cul\u003e\n    \u003cli\u003eFemoral artery exposure and operative access\u003c\/li\u003e\n    \u003cli\u003eFemoral-popliteal bypass procedure planning\u003c\/li\u003e\n    \u003cli\u003eVascular graft preparation\u003c\/li\u003e\n    \u003cli\u003eSubcutaneous graft tunnelling\u003c\/li\u003e\n    \u003cli\u003eProximal and distal vessel preparation\u003c\/li\u003e\n    \u003cli\u003eEnd-to-end vascular anastomosis\u003c\/li\u003e\n    \u003cli\u003eEnd-to-side vascular anastomosis\u003c\/li\u003e\n    \u003cli\u003eVascular clamp and instrument handling\u003c\/li\u003e\n    \u003cli\u003eNeedle control and accurate suture placement\u003c\/li\u003e\n    \u003cli\u003eSuture spacing and tension management\u003c\/li\u003e\n    \u003cli\u003eAssessment of vascular repairs under simulated flow\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch2\u003eRealistic Multi-Level Operative Access\u003c\/h2\u003e\n\n  \u003cp\u003e\n    Unlike a flat vascular suturing pad, this full-leg model requires learners\n    to work through defined operative openings. This recreates the restricted\n    access, working depth and instrument angles encountered during open\n    lower-limb vascular procedures.\n  \u003c\/p\u003e\n\n  \u003cp\u003e\n    A \u003cstrong\u003eLifeLike Medium Femoral Artery\u003c\/strong\u003e is positioned within the\n    groin cavity, while \u003cstrong\u003eLifeLike Small Femoral Arteries\u003c\/strong\u003e are\n    positioned within the above-knee and below-knee openings.\n  \u003c\/p\u003e\n\n  \u003cp\u003e\n    The cavities running between these access points provide a pathway through\n    which a graft can be tunnelled, allowing the complete bypass sequence to be\n    practised on a single training platform.\n  \u003c\/p\u003e\n\n  \u003ch2\u003eRequired Femoral Artery Models\u003c\/h2\u003e\n\n  \u003cp\u003e\n    Each complete training setup requires:\n  \u003c\/p\u003e\n\n  \u003cul\u003e\n    \u003cli\u003e\n      \u003cstrong\u003e1 × LifeLike Medium Femoral Artery\u003c\/strong\u003e for the groin cavity\n    \u003c\/li\u003e\n    \u003cli\u003e\n      \u003cstrong\u003e2 × LifeLike Small Femoral Arteries\u003c\/strong\u003e for the above-knee\n      and below-knee cavities\n    \u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003cp\u003e\n    The artery models are replaceable, allowing the main leg simulator to be\n    retained and reused across multiple training sessions. Please select the\n    required vessel models separately unless they are specifically included\n    within your quotation or training package.\n  \u003c\/p\u003e\n\n  \u003ch2\u003eOptional Pulsatile Flow System\u003c\/h2\u003e\n\n  \u003cp\u003e\n    The simulator is available either with or without a pulsatile pump. The\n    pump configuration circulates water through the installed femoral artery\n    models, enabling repairs and anastomoses to be examined under simulated\n    vascular flow.\n  \u003c\/p\u003e\n\n  \u003cp\u003e\n    This provides a valuable final stage to the training exercise by allowing\n    learners and instructors to identify leakage and assess the overall quality\n    of the completed vascular repair.\n  \u003c\/p\u003e\n\n  \u003ch2\u003eSuitable for Professional Vascular Surgery Training\u003c\/h2\u003e\n\n  \u003cul\u003e\n    \u003cli\u003eVascular surgery trainees and fellows\u003c\/li\u003e\n    \u003cli\u003eConsultant-led surgical education\u003c\/li\u003e\n    \u003cli\u003eMedical schools and teaching hospitals\u003c\/li\u003e\n    \u003cli\u003eSurgical skills laboratories\u003c\/li\u003e\n    \u003cli\u003eClinical simulation centres\u003c\/li\u003e\n    \u003cli\u003eFemoral-popliteal bypass courses\u003c\/li\u003e\n    \u003cli\u003eVascular anastomosis workshops\u003c\/li\u003e\n    \u003cli\u003eMedical device training and demonstrations\u003c\/li\u003e\n    \u003cli\u003eCompetency-development programmes\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch2\u003eProduct Specifications\u003c\/h2\u003e\n\n  \u003cdiv style=\"overflow-x:auto;\"\u003e\n    \u003ctable style=\"width:100%; border-collapse:collapse;\"\u003e\n      \u003ctbody\u003e\n        \u003ctr\u003e\n          \u003cth style=\"width:34%; text-align:left; padding:11px; border-bottom:1px solid #dddddd;\"\u003e\n            Product\n          \u003c\/th\u003e\n          \u003ctd style=\"padding:11px; border-bottom:1px solid #dddddd;\"\u003e\n            LifeLike Long Femoral Leg Simulator\n          \u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n          \u003cth style=\"text-align:left; padding:11px; border-bottom:1px solid #dddddd;\"\u003e\n            Approximate dimensions\n          \u003c\/th\u003e\n          \u003ctd style=\"padding:11px; border-bottom:1px solid #dddddd;\"\u003e\n            100 × 30 × 15 cm\n          \u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n          \u003cth style=\"text-align:left; padding:11px; border-bottom:1px solid #dddddd;\"\u003e\n            Approximate weight\n          \u003c\/th\u003e\n          \u003ctd style=\"padding:11px; border-bottom:1px solid #dddddd;\"\u003e\n            2.5 kg\n          \u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n          \u003cth style=\"text-align:left; padding:11px; border-bottom:1px solid #dddddd;\"\u003e\n            Operative openings\n          \u003c\/th\u003e\n          \u003ctd style=\"padding:11px; border-bottom:1px solid #dddddd;\"\u003e\n            Groin, above knee and below knee\n          \u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n          \u003cth style=\"text-align:left; padding:11px; border-bottom:1px solid #dddddd;\"\u003e\n            Primary procedure\n          \u003c\/th\u003e\n          \u003ctd style=\"padding:11px; border-bottom:1px solid #dddddd;\"\u003e\n            Femoral-popliteal bypass\n          \u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n          \u003cth style=\"text-align:left; padding:11px; border-bottom:1px solid #dddddd;\"\u003e\n            Training applications\n          \u003c\/th\u003e\n          \u003ctd style=\"padding:11px; border-bottom:1px solid #dddddd;\"\u003e\n            Graft tunnelling, vessel preparation and vascular anastomosis\n          \u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n          \u003cth style=\"text-align:left; padding:11px; border-bottom:1px solid #dddddd;\"\u003e\n            Pump options\n          \u003c\/th\u003e\n          \u003ctd style=\"padding:11px; border-bottom:1px solid #dddddd;\"\u003e\n            Available with or without pulsatile pump\n          \u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n          \u003cth style=\"text-align:left; padding:11px; border-bottom:1px solid #dddddd;\"\u003e\n            Pump specification\n          \u003c\/th\u003e\n          \u003ctd style=\"padding:11px; border-bottom:1px solid #dddddd;\"\u003e\n            120V\/220V with Type B plug\n          \u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n          \u003cth style=\"text-align:left; padding:11px; border-bottom:1px solid #dddddd;\"\u003e\n            Material properties\n          \u003c\/th\u003e\n          \u003ctd style=\"padding:11px; border-bottom:1px solid #dddddd;\"\u003e\n            Non-toxic, biohazard-free and odourless\n          \u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n          \u003cth style=\"text-align:left; padding:11px; border-bottom:1px solid #dddddd;\"\u003e\n            Latex warning\n          \u003c\/th\u003e\n          \u003ctd style=\"padding:11px; border-bottom:1px solid #dddddd;\"\u003e\n            This product contains latex\n          \u003c\/td\u003e\n        \u003c\/tr\u003e\n\n        \u003ctr\u003e\n          \u003cth style=\"text-align:left; padding:11px;\"\u003e\n            Intended use\n          \u003c\/th\u003e\n          \u003ctd style=\"padding:11px;\"\u003e\n            Professional surgical education and simulation only\n          \u003c\/td\u003e\n        \u003c\/tr\u003e\n      \u003c\/tbody\u003e\n    \u003c\/table\u003e\n  \u003c\/div\u003e\n\n  \u003ch2\u003eAvailable Configurations\u003c\/h2\u003e\n\n  \u003cul\u003e\n    \u003cli\u003e\n      \u003cstrong\u003eLong Femoral Leg Simulator with Pump:\u003c\/strong\u003e Includes the\n      pulsatile flow system for testing completed vascular repairs under\n      simulated circulation.\n    \u003c\/li\u003e\n\n    \u003cli\u003e\n      \u003cstrong\u003eLong Femoral Leg Simulator without Pump:\u003c\/strong\u003e Suitable for\n      procedural, tunnelling and anastomosis training where simulated flow is\n      not required.\n    \u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003cdiv style=\"margin:24px 0; padding:18px; background:#f4f7f8; border-left:4px solid #173f4f;\"\u003e\n    \u003cp style=\"margin:0 0 8px;\"\u003e\n      \u003cstrong\u003eImportant ordering information\u003c\/strong\u003e\n    \u003c\/p\u003e\n\n    \u003cp style=\"margin:0;\"\u003e\n      Replaceable femoral artery models should be selected separately unless\n      they are specifically included within your quotation. The manufacturer\n      specifies a Type B pump plug, so UK power compatibility should be\n      confirmed when ordering the pump version.\n    \u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\n  \u003ch3\u003eWhich procedure is this simulator designed for?\u003c\/h3\u003e\n\n  \u003cp\u003e\n    It is primarily designed for practising femoral-popliteal bypass surgery,\n    including operative access, graft tunnelling, vessel preparation and\n    vascular anastomosis.\n  \u003c\/p\u003e\n\n  \u003ch3\u003eHow many vessel models are required?\u003c\/h3\u003e\n\n  \u003cp\u003e\n    A complete training setup requires one Medium Femoral Artery for the groin\n    and two Small Femoral Arteries for the above-knee and below-knee openings.\n  \u003c\/p\u003e\n\n  \u003ch3\u003eDoes the simulator include a pump?\u003c\/h3\u003e\n\n  \u003cp\u003e\n    The product is available in two configurations. Select either the complete\n    version with a pulsatile pump or the simulator without a pump.\n  \u003c\/p\u003e\n\n  \u003ch3\u003eCan graft tunnelling be practised?\u003c\/h3\u003e\n\n  \u003cp\u003e\n    Yes. Internal cavities run between the operative openings and are\n    specifically designed to support vascular graft tunnelling practice.\n  \u003c\/p\u003e\n\n  \u003ch3\u003eDoes the product contain latex?\u003c\/h3\u003e\n\n  \u003cp\u003e\n    Yes. The manufacturer states that the Long Femoral Leg Simulator contains\n    latex.\n  \u003c\/p\u003e\n\n  \u003cdiv style=\"margin-top:25px; padding:20px; background:#173f4f; color:#ffffff; border-radius:8px;\"\u003e\n    \u003ch3 style=\"margin-top:0; color:#ffffff;\"\u003e\n      Need a Complete Fem-Pop Bypass Training Package?\n    \u003c\/h3\u003e\n\n    \u003cp style=\"margin-bottom:0; color:#ffffff;\"\u003e\n      Contact SurgiSim for institutional quotations, replacement femoral\n      arteries or assistance selecting the correct simulator and pump\n      configuration.\n    \u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"LifeLike BioTissue","offers":[{"title":"Without Pump","offer_id":63238131253578,"sku":"LL-TRN-1267","price":3500.0,"currency_code":"GBP","in_stock":true},{"title":"With Pump","offer_id":63238131286346,"sku":"LL-TRN-1268","price":4200.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1035\/1378\/4650\/files\/lifelike-biotissue-long-femoral-leg-simulatoradvanced-surgical-simulation-4747811.jpg?v=1787463736","url":"https:\/\/surgisim.co.uk\/products\/lifelike-biotissue-lifelike-long-femoral-leg-simulator-no-pump-1267","provider":"SurgiSim","version":"1.0","type":"link"}